AC not cooling: what to check, in order
When an AC runs but does not cool, the cause is most often a thermostat setting, a clogged air filter, or an outdoor unit that has lost power or is choked with debris. Ice on the copper lines, a backed up condensate drain or a tripped breaker are the next things to check. If you see ice, smell burning or a breaker trips twice, turn the system off and call a licensed HVAC contractor.
Start at the thermostat
- Mode. It should say Cool, not Heat, Off or Fan.
- Setpoint. Set it a few degrees below the room temperature so the system has a reason to start.
- Fan setting. On Auto, the fan runs only while the system cools. On On, it keeps blowing between cycles, and that air can feel warm.
- Blank screen. Try fresh batteries. Some thermostats draw power from the system itself, so a blank screen can also mean the indoor unit shut itself down, which the drain section below explains.
Pull out the air filter
The filter sits in a slot at the indoor unit or behind a return grille on a wall or ceiling. Hold it up to a light. If you cannot see light through it, replace it with the same size, which is printed on the frame, and point the arrow toward the unit.
A clogged filter starves the system of air. Less air across the indoor coil means weaker cooling, and over time it can let ice build up on that coil.
Go outside to the condenser
With the thermostat calling for cooling, the outdoor unit should hum and its top fan should spin.
- Nothing running. Look for the disconnect, a small gray box on the wall near the unit. It holds a pull out block or a lever switch, and it is sometimes left off after service. Then check the breaker for the outdoor unit in your main panel.
- Debris. Leaves, grass clippings and plants packed against the fins block airflow. Turn the power off at the disconnect, clear it by hand, and rinse the fins gently with a garden hose. Skip the pressure washer, since it bends the thin fins.
- Hums but the fan will not spin. Turn it off. That often points to a failed capacitor or fan motor, and capacitors hold a stored electrical charge. Leave it to a pro.
Ice on the lines or the indoor coil
Look at the larger insulated copper line where it enters the outdoor unit, and at the indoor coil if you can see it. A coating of ice there means something is wrong.
Set the thermostat to Off and the fan to On. Room air blowing across the ice melts it over a few hours, so put towels down for the water. Replace the filter and make sure vents and return grilles are not blocked by furniture.
If the ice comes back, low refrigerant from a leak is a common cause. That is not a homeowner job; a licensed HVAC contractor has to find and repair the leak.
The condensate drain and its safety switch
An AC pulls water out of the air. It drips into a pan under the indoor coil and leaves through a plastic drain line, often to a floor drain, a small pump or outside. Many systems have a float switch on the pan or line that shuts cooling off when water backs up, so the unit does not overflow into a ceiling or basement.
If you find water in the pan, the line is likely clogged. A wet/dry vacuum held to the outside end of the line can pull the clog free. Once the water drains, cooling often starts again. If water keeps collecting, call for service.
Breakers, and when to call
Most central systems use two circuits: one for the outdoor unit and one for the indoor air handler or furnace. A tripped breaker sits in the middle or off position. Push it fully off, then on, once. If it trips again, leave it off; our breaker guide explains why.
Turn the system off and call a licensed HVAC contractor if you smell burning, hear grinding or loud buzzing, the ice returns, water keeps showing up, or the outdoor unit runs while the air inside stays warm. In Maryland, HVAC contractors are licensed by the Maryland Board of Heating, Ventilation, Air Conditioning and Refrigeration Contractors, which has a license search on its website.
Questions people ask
Why is my AC running but not cooling the house?
Check for a dirty filter, a blocked or unpowered outdoor unit, and ice on the copper lines. If all three look fine, the system may be low on refrigerant or have a failing part.
How cold should the air from my vents be?
On a working system, air at the supply vents is often about 15 to 20 degrees cooler than the air going into the return grille.
Can a smart thermostat warn me the AC is struggling?
Many can. They show how long the system runs each day and can alert you when the indoor temperature keeps rising while it is set to cool. Strech, the home operating system, is built to read signals like these and connect you with a vetted local pro, with the price shown before any work starts.